E.F. Johnson Company VR-CM50 Guia de Instalação

Consulte online ou descarregue Guia de Instalação para Desumidificadores E.F. Johnson Company VR-CM50. E.F. Johnson Company VR-CM50 Installation guide Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 50
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
VR-CM50 CONSOLE SYSTEM
INSTALLATION GUIDE
Second Printing
February 1996
Supersedes 004-3039-274 May 1995
Vista de página 0
1 2 3 4 5 6 ... 49 50

Resumo do Conteúdo

Página 1 - INSTALLATION GUIDE

VR-CM50 CONSOLE SYSTEMINSTALLATION GUIDESecond PrintingFebruary 1996Supersedes 004-3039-274 May 1995

Página 2

PRE-INSTALLATION INFORMATION1-2February 1996Part No. 004-3039-2741.1.5 TOOLS REQUIREDThe following tools are needed for the mechani-cal assembly and

Página 3

2-1February 1996Part No. 004-3039-274CENTRAL PROCESSOR PACKAGE INSTALLATIONSECTION 2 CENTRAL PROCESSOR PACKAGE INSTALLATION2.1 LOCATION OF THE CENTR

Página 4

CENTRAL PROCESSOR PACKAGE INSTALLATION2-2February 1996Part No. 004-3039-274Figure 2-1 REAR VIEW - JOINING TWO CPU CABINETS

Página 5 - TABLE OF CONTENTS

CENTRAL PROCESSOR PACKAGE INSTALLATION2-3February 1996Part No. 004-3039-2742.3 CONNECTION OF THE CENTRAL PRO-CESSOR PACKAGE CABLESWhen multiple CPP ca

Página 6 - LIST OF FIGURES

CENTRAL PROCESSOR PACKAGE INSTALLATION2-4February 1996Part No. 004-3039-2742.4 MOUNTING OF SURGE ARRESTOR BOX-ES AND GROUND BRACKET2.4.1 PLACEMENT OF

Página 7 - LIST OF TABLES

CENTRAL PROCESSOR PACKAGE INSTALLATION2-5February 1996Part No. 004-3039-2742.5 GROUNDING THE SYSTEMProper grounding is the single most important consi

Página 8

CENTRAL PROCESSOR PACKAGE INSTALLATION2-6February 1996Part No. 004-3039-274Figure 2-5 COMMON GROUND BRACKET ASSEMBLYplacement of the connections on

Página 9

CENTRAL PROCESSOR PACKAGE INSTALLATION2-7February 1996Part No. 004-3039-2742.7 CPP I/O PANELSCPPs with a capacity of twenty or more cards will have on

Página 10 - Part No. 004-3039-274

CENTRAL PROCESSOR PACKAGE INSTALLATION2-8February 1996Part No. 004-3039-2742.8 SAMPLE CUSTOMER DATA SHEETSThe Customer Data Sheets which are included

Página 11

CENTRAL PROCESSOR PACKAGE INSTALLATION2-9February 1996Part No. 004-3039-274Figure 2-8 RTL I/O PANEL ASSIGNMENTSFigure 2-9 VOTING COMPARATOR DISPLA

Página 13

CENTRAL PROCESSOR PACKAGE INSTALLATION2-10February 1996Part No. 004-3039-274Figure 2-10 LOGGING RECORDERFigure 2-11 AUXILIARY CONTROL RELAY ASSIGN

Página 14 - C A U T I O N

CENTRAL PROCESSOR PACKAGE INSTALLATION2-11February 1996Part No. 004-3039-2742.9 WIRING OF SURGE ARRESTOR BOXESTypically, connectors P9 through P13 on

Página 15 - I M P O R T A N T

CENTRAL PROCESSOR PACKAGE INSTALLATION2-12February 1996Part No. 004-3039-2742.10 DISPATCH POSITION CONNECTIONSEach dispatch position will plug directl

Página 16

CENTRAL PROCESSOR PACKAGE INSTALLATION2-13February 1996Part No. 004-3039-274Typically, logging recorder audio appears on con-nector P14 on the standar

Página 17

CENTRAL PROCESSOR PACKAGE INSTALLATION2-14February 1996Part No. 004-3039-274relays 9 through 16 mount at the top of the panel. The Customer Data Sh

Página 18 - 20+ Card

CENTRAL PROCESSOR PACKAGE INSTALLATION2-15February 1996Part No. 004-3039-2742.16 CONNECTION TO AUXILIARY CONTROL FUNCTIONS (14 Card Central Cabinet)Th

Página 19

CENTRAL PROCESSOR PACKAGE INSTALLATION2-16February 1996Part No. 004-3039-2742.17 PA SYSTEM FEEDThe CPP can be connected to a building public address t

Página 20

3-1February 1996Part No. 004-3039-274CABINETRY ASSEMBLY FOR CRT CONSOLE SYSTEMSSECTION 3 CABINETRY ASSEMBLY FOR CRT CONSOLE SYSTEMS3.1 INTRODUCTION

Página 21

CABINETRY ASSEMBLY FOR CRT CONSOLE SYSTEMS3-2February 1996Part No. 004-3039-2743.4 MAIN CONSOLE ASSEMBLY4. Remove the front and rear keylocked enclosu

Página 22

CABINETRY ASSEMBLY FOR CRT CONSOLE SYSTEMS3-3February 1996Part No. 004-3039-274Figure 3-4 FORMICA SURFACE ARRANGEMENT2. Mark the console face where

Página 23

VR-CM50 CONSOLE SYSTEMINSTALLATION GUIDECopyright 1995 by the E.F. Johnson CompanyThe E.F. Johnson Company designs and manufactures two-way radio equ

Página 24

CABINETRY ASSEMBLY FOR CRT CONSOLE SYSTEMS3-4February 1996Part No. 004-3039-274Figure 3-6 WRITING SUPPORT RAIL MOUNTINGNOTE: If the console has a k

Página 25

CABINETRY ASSEMBLY FOR CRT CONSOLE SYSTEMS3-5February 1996Part No. 004-3039-274Figure 3-7 CTP TRAY3.8 ATTACHING THE FORMICA WRITING SUR-FACE1. Posit

Página 26

CABINETRY ASSEMBLY FOR CRT CONSOLE SYSTEMS3-6February 1996Part No. 004-3039-274Figure 3-10 FORMICA WRITING SURFACE AND TRIMReplace all keylocked enc

Página 27

CABINETRY ASSEMBLY FOR CRT CONSOLE SYSTEMS3-7February 1996Part No. 004-3039-274cabinetry consisting of a pie-shape sections along with 2 or more cabin

Página 28

CABINETRY ASSEMBLY FOR CRT CONSOLE SYSTEMS3-8February 1996Part No. 004-3039-2743.10.4 UNIVERSAL PENCIL DRAWER MOUNT-ING (OPTION 4)1. Remove the penci

Página 29

CABINETRY ASSEMBLY FOR CRT CONSOLE SYSTEMS3-9February 1996Part No. 004-3039-274Figure 3-16 PIE SUPPORT RAIL MOUNTING3.10.7 CRT MONITOR SHELF - FXM-

Página 30

CABINETRY ASSEMBLY FOR CRT CONSOLE SYSTEMS3-10February 1996Part No. 004-3039-274Figure 3-18 CRT MONITOR SHELFTable 3-1 MONITOR SHELF HARDWAREQty.

Página 31

4-1February 1996Part No. 004-3039-274CRT-BASED ELECTRONICS ASSEMBLY PART ISECTION 4 CRT-BASED ELECTRONICS ASSEMBLY PART I4.1 INTRODUCTIONSince you h

Página 32

CRT-BASED ELECTRONICS ASSEMBLY PART I4-2February 1996Part No. 004-3039-274Figure 4-2 CIP POWER SUPPLYMount The CIP TrayInstall the CIP tray at the l

Página 33

CRT-BASED ELECTRONICS ASSEMBLY PART I4-3February 1996Part No. 004-3039-274Figure 4-3 CIP TRAY WITH MICROPHONE3. After the CIP tray is mounted, conne

Página 35

CRT-BASED ELECTRONICS ASSEMBLY PART I4-4February 1996Part No. 004-3039-274This page intentionally left blank.

Página 36

5-1February 1996Part No. 004-3039-274CRT-BASED ELECTRONICS ASSEMBLY PART IISECTION 5 CRT-BASED ELECTRONICS ASSEMBLY PART II5.1 INTRODUCTIONIf you ha

Página 37

CRT-BASED ELECTRONICS ASSEMBLY PART II5-2February 1996Part No. 004-3039-2745.4 CONNECT THE CRT INTERFACE PROCESSOR (CIP) TRAY CABLESRefer to Figure 5-

Página 38

CRT-BASED ELECTRONICS ASSEMBLY PART II5-3February 1996Part No. 004-3039-2745.5 INSTALL THE CRT MONITOR5.5.1 CRT MONITOR CONNECTIONSRefer to Figure 5-

Página 39

CRT-BASED ELECTRONICS ASSEMBLY PART II5-4February 1996Part No. 004-3039-2745.7 INSTALL CRT TRACKBALL OPTION/MOUSE OPTIONTRACKBALL OPTION - TDV-OP490MO

Página 40

CRT-BASED ELECTRONICS ASSEMBLY PART II5-5February 1996Part No. 004-3039-2741. Remove the hole plug from the left side of the head-set jack housing.2.

Página 41

CRT-BASED ELECTRONICS ASSEMBLY PART II5-6February 1996Part No. 004-3039-274This page intentionally left blank.

Página 42 - (A1709230) Cable Conn

6-1February 1996Part No. 004-3039-274EQUIPMENT CHECK-OUT AND ADJUSTMENTSSECTION 6 EQUIPMENT CHECK-OUT AND ADJUSTMENTS6.1 INITIAL POWER-UP AND CHECK-

Página 43

EQUIPMENT CHECK-OUT AND ADJUSTMENTS6-2February 1996Part No. 004-3039-2747. Observe the LEDs on the channel modules. On module-based consoles, each cha

Página 44

EQUIPMENT CHECK-OUT AND ADJUSTMENTS6-3February 1996Part No. 004-3039-274Headset Receive LimitThe receive audio sensitivity and the method of handling

Página 45

TABLE OF CONTENTS11 PRE-INSTALLATION INFORMATION1.1 RECEIVING INFORMATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 46

EQUIPMENT CHECK-OUT AND ADJUSTMENTS6-4February 1996Part No. 004-3039-274SCREEN 1______________________________________________________________________

Página 47

TABLE OF CONTENTS (CONT.)24 CRT-BASED ELECTRONICS ASSEMBLY PART I4.1 INTRODUCTION. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 48

TABLE OF CONTENTS (CONT.)32-14 14 CARD RELAY PANEL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Página 50

1-1February 1996Part No. 004-3039-274PRE-INSTALLATION INFORMATIONSECTION 1 PRE-INSTALLATION INFORMATION1.1 RECEIVING INFORMATIONI M P O R T A N TThi

Comentários a estes Manuais

Sem comentários